Fault Finding Series Navigation:
Pressure problems, weak flow and controller error codes are common issues in water-fed pole window cleaning systems. These faults slow productivity, waste water and create repeated interruptions at the brush. Fortunately, most pressure-related problems can be diagnosed quickly by following this structured guide. For replacement parts, browse our pumps, controllers and WFP accessories.
Understanding Pressure in Water-Fed Systems
Water-fed systems depend on a balance of pump performance, unrestricted flow, correct hose diameter and proper controller programming. When this balance is disturbed, you may experience weak flow, pulsing, high-pressure spikes or error codes such as DE, PS or FL. Before assuming the pump is faulty, always inspect hoses, jets, filters and controller calibration.
- Weak or inconsistent flow
- Pump cycling on and off
- Sudden pressure spikes
- Brush receiving too little water
- DE, PS, FL or overload warnings
Step 1 – Poor Flow vs Low Pressure
Poor flow and low pressure are related but not the same issue. Understanding the difference reduces diagnostic time.
Poor Flow
Low water volume reaching the brush. Common causes include blocked jets, dirty filters, kinked hose, airlocks or incorrect FLOW settings.
Low Pressure
Pump cannot build or maintain pressure. Causes include valve wear, leaks, loose fittings, or incorrect CAL settings.
Step 2 – Hose, Brush Jets & Fittings
Brush jets and hose lines cause a large percentage of pressure-related faults. Firstly, remove brush jets and test flow without them. If flow increases significantly, the jets were restricted. Next, inspect hose lines for internal collapse, crushed points or kinks. Even small leaks in fittings reduce pressure and make the controller think the system is blocked. Replacement hose can be found in our Window Cleaning Hose section.
Step 3 – Check Filters & Pump Demand
A partially blocked inlet filter forces the pump to work harder, causing pressure fluctuations and controller errors. Remove the filter bowl and check for grit, resin dust, algae or trapped air. A blocked filter can trigger a false “DE” even if the system is not blocked. Replacement filters are available in our WFP Accessories.
Step 4 – Pump Valve & Diaphragm Wear
If flow starts strong but quickly weakens, or if the pump surges repeatedly, the internal valves may be sticking. Dirt, resin particles or frozen pump damage often cause valve problems. Disconnect the outlet hose and test pump output directly. Weak, pulsing or dribbling output usually indicates worn valves or diaphragm plates.
Step 5 – Controller Settings & Pressure Calibration
Incorrect controller settings cause many pressure problems. If FLOW is too low, the controller pulses. If CAL is too low, the controller repeatedly shows DE or PS.
Firstly, increase FLOW to a mid-range setting (40–60). Then raise CAL in small steps (+2 at a time) until the system stabilises. You can find replacement controllers in our Pump Controller category.
Step 6 – Understanding Controller Error Codes
DE – Dead End
The system believes there is a blockage. Often caused by blocked jets, collapsed hose, filter blockage or low CAL setting.
PS – Pump Stall
The pump cannot turn freely. Causes include valve issues, seized motor, frozen pump or blockage after the pump.
FL – Flow Error
Overload
The pump is drawing too much current. Often indicates internal motor wear, seized pump or burnt connectors.
Step 7 – Electrical Checks & Direct Pump Test
Weak voltage or burnt wiring can reduce pressure. Inspect all connectors for corrosion or loose terminals. Low voltage causes the pump to run weakly and lose pressure. To confirm pump condition, disconnect it from the controller and power it directly from a 12V battery. Strong pressure indicates a controller or wiring fault; weak pressure indicates pump wear.
When Replacement Is Necessary
Replace components when filters clog repeatedly, hoses collapse internally, pumps produce weak output on direct test or controllers cannot hold calibration. Regular inspection prevents larger faults from developing.
Final Tips for Long-Term Pressure Stability
Weekly filter cleaning, flushing brush jets, keeping hoses free from crushing and maintaining accurate FLOW/CAL settings dramatically reduce pressure-related issues. Additionally, storing your system in frost-free conditions prevents valve and diaphragm damage.
Need Pump or Controller Support?
Browse pumps, controllers and accessories at the Window Cleaning Stuff Shop. Fast UK delivery on thousands of items.
Related Products
- Shurflo Pumps – Full Range
- Pump Controllers
- Pump Motor Protection Cap
- Pump Diagnostic Lead
- Window Cleaning Hose
Explore More Guides
For more system troubleshooting advice, visit our Blog.