Prochem Heat ‘N’ Run AC3001
Original price was: £825.00.£660.00Current price is: £660.00. exc. VAT
1 in stock
The Prochem Heat ‘N’ Run (AC3001) is a 2.8 kW self-contained in-line heater engineered exclusively for the Prochem Steempro and Galaxy carpet soil extractor ranges. It delivers a continuous flow of hot cleaning solution to boost soil suspension, accelerate pre-spray chemistry, and cut cleaning time on heavy traffic lane soiling — all without replacing your existing machine.
in-line heater carpet extractor
hot water extraction upgrade
Steempro heater attachment
carpet cleaning accessory UK
2.8kW inline heater
Galaxy extractor accessory
- 2.8 kW stainless steel heat tube — continuous hot solution output throughout the job
- Fits Prochem Steempro & Galaxy ranges; slots directly onto existing heater mounting plates
- Dual-thermostat safety system — 65°C operating thermostat plus re-settable hi-limit cut-off
- CE-compliant isolated electrical unit — safe for professional use around water
- 25 ft power cable, illuminated rocker switch, and heat indicator lamp
- Mounts off the floor on the machine — neat, professional working setup
Prochem Heat 'N' Run AC3001 — In-Line Carpet Extractor Heater for Steempro & Galaxy
The Prochem Heat 'N' Run (AC3001) is a 2.8 kW self-contained in-line heater built exclusively for the Prochem Steempro and Galaxy carpet soil extractor ranges. It installs between your machine's solution outlet and the wand hose, heating cold tap water on demand to a regulated 65°C. The result: hotter chemistry, faster soil suspension, and shorter dwell times on every job.
Designed for carpet cleaning contractors and facilities management teams across the UK, the AC3001 turns a cold-water-only machine into a hot water extraction unit without any plumbing modifications. It slots onto the standard Steempro heater mounting plate and powers from a standard 13 A socket via its 25 ft cable.
|
2.8 kW
Heating Output
|
65°C
Operating Thermostat
|
25 ft
Power Cable Reach
|
2-in-1
Thermostat Safety System
|
Why UK Professionals Trust Prochem
Prochem Europe has supplied the professional carpet and fabric cleaning industry for over four decades. Their Steempro and Galaxy extractors are the dominant platform in the UK contract cleaning market. The Heat 'N' Run range exists specifically to solve a real-world operational problem: UK domestic properties and commercial buildings without dedicated hot water supplies near the work area. Rather than relying on a distant hot tap or buying an entirely new machine, contractors add the AC3001 and gain consistent, regulated heat on every site they visit.
The AC3001's stainless steel heat tube and CE-compliant isolated electrical housing reflect trade-grade engineering — not consumer-grade components. It tolerates daily commercial use, the chemical loads professional pre-sprays require, and the demands of hard UK water areas with the correct maintenance routine.
The AC3001 suits any operator running Prochem Steempro or Galaxy equipment who needs reliable hot water extraction without site-dependent access to a hot feed. Typical users include:
|
|
||||
|
|
Technical Specifications
| Specification | Detail |
|---|---|
| Product Code | AC3001 |
| Heating Element Power | 2.8 kW stainless steel heat tube |
| Operating Thermostat | 65°C |
| Safety Thermostat | Re-settable hi-limit cut-off (manual reset on body casing) |
| Electrical Safety | CE-compliant isolated electrical unit |
| Machine Compatibility | Prochem Steempro & Galaxy carpet soil extractor ranges |
| Mounting | Fits standard Steempro heater mounting plates — no modification needed |
| Power Cable Length | 25 ft (7.6 m) |
| Switch Type | Illuminated rocker switch with heat indicator lamp |
| Installation Type | In-line between solution outlet and wand hose — no plumbing required |
With vs Without the Heat 'N' Run
| Factor | Cold Water Extraction Only | With AC3001 Fitted |
|---|---|---|
| Soil Suspension | Reduced — greasy soils resist cold water | Improved — heat melts greasy traffic lane deposits |
| Pre-Spray Activation | Slower chemical reaction at ambient temperature | Faster — heat accelerates detergent chemistry |
| Dwell Time Required | Longer dwell needed on heavy soiling | Reduced — less time per room, more jobs per day |
| Site Dependency | Relies on accessing hot tap near work area | Self-contained — works from any cold water supply |
| Machine Cost | — | Lower cost than replacing machine with a heated model |
⚠ Pro Tip: Always Follow the Power-Down Sequence
The most common cause of premature element failure is switching the heater off at the same time as the machine. Instead, turn off the rocker switch 2–3 minutes before you finish the final pass. Keep the extractor running and continue pressing the wand trigger to push cold water through the heat tube. This flushes residual heat from the stainless steel core and prevents the element burning out against trapped hot water. If the heat indicator lamp is on but no heat is produced, the hi-limit thermostat has tripped — let the unit cool fully, then press the manual reset button on the body casing.
How to Use the Prochem Heat 'N' Run AC3001
|
1
|
Fill the extractor solution tank — use cold tap water and add your pre-measured liquid chemical. If you use a powdered product, premix it thoroughly in a separate bucket first to prevent undissolved particles clogging the heater core. |
|
2
|
Mount the AC3001 — slide the Heat 'N' Run onto the Steempro heater mounting plate. Connect the in-line hose fittings between the machine solution outlet and your wand hose. Check both brass quick-connect fittings are fully seated and not leaking. |
|
3
|
Prime the extractor pump — switch the machine on and press the wand trigger until water flows freely through the system. Confirm there is active water flow before touching the heater switch. |
|
4
|
Switch on the heater — flip the illuminated rocker switch to the ON position. The heat indicator lamp lights immediately. Allow 2–3 minutes for the 2.8 kW stainless steel heat tube to reach operating temperature before beginning extraction passes. |
|
5
|
Clean normally — the 65°C thermostat regulates solution temperature automatically throughout the job. Apply your pre-spray, allow the recommended dwell time, then extract using standard overlapping wand passes. |
|
6
|
Power down the heater first — with 2–3 minutes of cleaning remaining, switch the rocker to OFF. Continue pressing the wand trigger to flush cold water through the heat tube. This step protects the element and extends service life considerably. |
|
7
|
Flush and store — at the end of the working day, run a clean bucket of warm water through the system to remove detergent residues. Drain completely, wipe brass connectors with a light application of WD-40, and store the unit in a frost-free location. |
Maintenance & Safety
- Never switch the heater on without active water flow through the system — running the element dry causes immediate, irreparable damage to the stainless steel heat tube.
- Always switch the heater off 2–3 minutes before the machine — continue flushing water through the wand to cool the element before disconnecting power.
- Electrical safety: this is a CE-compliant isolated electrical unit — do not operate with a damaged power cable. Inspect the 25 ft cable for cuts, fraying, or kinks before each use. Do not use with an extension cable that is not rated for outdoor/damp conditions.
- Premix all powdered cleaning chemicals in a separate bucket before adding to the solution tank. Undissolved granules will block the heater core and machine pump.
- Frost protection is critical — never store or transport the unit in temperatures at or near freezing. Residual water inside the core expands when frozen and will split the heat tube permanently.
- In hard water areas, run a mild citric acid descaler through the cold unit periodically to remove limescale from the heating core. Flush thoroughly with clean water after descaling and do not allow acid to remain inside the unit.
- Check brass quick-connect fittings monthly for signs of wear or weeping. Lubricate with silicone spray to prevent seizure under operating pressure.
- Inspect O-rings at the hose connections monthly. Replace any that show cracking or flattening to prevent leaks during use.
- If the hi-limit thermostat trips (lamp on, no heat), switch off, allow full cool-down, then press the manual reset button on the unit body. If it trips repeatedly, inspect the water flow rate through the system before restarting.
Frequently Asked Questions
Will the Prochem AC3001 in-line heater fit my machine?
The AC3001 is designed exclusively for the Prochem Steempro and Galaxy carpet soil extractor ranges. It slides directly onto the standard Steempro heater mounting plates with no modification. It is not compatible with other brands of extraction machine, and using it outside its specified compatibility may create safety risks and void any applicable warranty.
How does the hot water extraction upgrade work on a cold-water machine?
The AC3001 installs in-line between the machine's solution outlet and the wand hose. Cold water from the solution tank passes through the 2.8 kW stainless steel heat tube, which heats it continuously before it exits the wand. The 65°C thermostat maintains a consistent temperature throughout the job without any intervention from the operator.
What happens if the heater overheats?
The AC3001 uses a dual-thermostat safety system. The primary 65°C thermostat regulates normal operating temperature. If that thermostat fails or flow is interrupted, a secondary re-settable hi-limit safety thermostat cuts power to the element automatically. Once the unit has cooled completely, the operator resets it manually using the button on the body casing. This design meets CE requirements for an isolated electrical unit used in damp environments.
Can I use powdered carpet cleaning chemicals with the Heat 'N' Run?
Yes, but only if you premix them fully in a separate bucket of water before pouring the solution into the extractor tank. Undissolved powder granules will block the heater core and damage the machine pump. Liquid pre-sprays and traffic lane treatments pass through the unit without issue when used at correct dilutions.
Do I need to descale the Prochem in-line heater if I work in a hard water area?
Yes. Hard water calcium deposits build up on the internal surface of the stainless steel heat tube over time. This insulates the element, reduces heat output, and eventually causes the unit to overheat and trip. Run a mild citric acid descaler through the cold unit periodically, then flush thoroughly with clean water. Never leave descaling solution sitting in the unit and never descale under heat.
What is the correct shutdown procedure for the Heat 'N' Run?
Switch the heater rocker to OFF approximately 2–3 minutes before you finish extraction. Keep the machine running and continue pressing the wand trigger to push cold water through the heat tube. This cools the element before you disconnect power. Shutting the heater and machine off simultaneously is the most common cause of element burnout and is not covered under warranty.
Can the AC3001 be stored in a van overnight during winter?
No. Any residual water inside the heat tube will freeze at sub-zero temperatures, expand, and split the internal stainless steel core — a failure that is not repairable. After each job, drain the unit fully before transporting or storing. Keep it in a frost-free environment overnight. This is especially important during UK winter months when overnight van temperatures regularly fall below freezing.
Recommended Accessories
| Product | Why It Pairs with the AC3001 |
|---|---|
| Prochem Traffic Lane Cleaner | Hot solution activates traffic lane degreasers significantly faster than cold water — pair for maximum soil suspension on heavily used carpets. |
| Prochem Fibre & Fabric Rinse | Use as a daily end-of-job flush through the Heat 'N' Run to neutralise detergent residues and protect the heat tube from corrosive chemical build-up. |
| Citric Acid Descaler | Essential for operators in hard water areas. Regular descaling prevents limescale build-up on the stainless steel heat tube and maintains full 2.8 kW output. |
| Prochem Steempro Carpet Extractor | The AC3001's parent machine — the compatible extractor platform this heater was engineered for. Required for AC3001 operation. |
| Prochem Cleaning Wand | The downstream tool that delivers heated solution to the carpet face. A well-maintained wand with clean jets ensures even heat distribution across the cleaning path. |
Stop relying on site hot taps — start delivering hot water extraction on every job.
Free UK Mainland delivery · Non -stock item sourced directly from Prochem within 48 hours · 14-day returns on unused items.
| Add Prochem Heat 'N' Run AC3001 to Basket |
Only logged in customers who have purchased this product may leave a review.
Submit price match data
Price match
Request a price match for a product









Reviews
There are no reviews yet.