No-flow and intermittent flow issues are common problems in water-fed pole window cleaning systems. Fortunately, most of these faults are caused by simple issues such as blocked filters, kinked hoses, sticking pump valves or incorrect controller settings. This guide takes you through each potential cause step-by-step to help you identify the fault quickly and restore consistent water flow. For replacement parts, you can browse our pumps, controllers and WFP accessories.

Why No-Flow Problems Happen

Water-fed systems depend on a clean, unrestricted flow from the tank to the brush. When flow becomes weak, intermittent or stops entirely, the issue usually relates to one of the following areas: airlocks, filters, valves, hoses or controller settings.
Before assuming the pump is faulty, always start with basic checks.

  • Airlocks in pump or hose line
  • Blocked or dirty filters
  • Sticking inlet or outlet pump valves
  • Kinked or collapsed hoses
  • Incorrect controller calibration

Step 1 – Check Water Supply & Tank Outlet

Firstly, confirm that enough pure water is in the tank and that the pickup pipe is fully submerged. A pickup hose that draws air will immediately cause flow loss. Also inspect the tank outlet to ensure no debris is obstructing it and that the outlet valve is fully open.

Step 2 – Inspect Filters for Blockages

Blocked filters are one of the most common causes of no-flow and pulsing flow. Remove the clear inlet filter and check for grit, algae, resin dust or air trapped in the bowl. A blocked filter can also trigger a false “DE” warning on your controller. Replacement filters can be found in our WFP Accessories.

Step 3 – Check for Airlocks

Airlocks stop water reaching the brush even when the pump is running. Disconnect the hose from the brush head, run the pump at 100% FLOW and lift sections of the hose up and down to force the trapped air out. Once flow becomes steady, reconnect the brush and test again.

Step 4 – Inspect Hoses & Reels

Kinked or collapsed hoses can cause intermittent flow, especially when using microbore or minibore hose. Check for flat sections, crushed fittings or tight reel rollers. Testing with another hose can quickly confirm whether the hose is the cause. Replacement hose options are available in our Window Cleaning Hose section.

Step 5 – Check Pump Valves for Sticking

If the pump runs but produces weak or pulsing flow, the internal valves may be sticking. Common causes include dirt from the tank, resin particles, frozen pump damage or long periods without use. Disconnect the outlet hose from the pump and run it briefly. If the output pulses or dribbles, the valves may be blocked or worn.

Step 6 – Controller Settings & Calibration

Incorrect controller settings often cause pulsing, weak flow or false “DE” warnings. Firstly, set FLOW to a mid-range value (40–60). Then increase CAL incrementally by two points until flow stabilises. If the controller continues pulsing, wiring faults or pump issues may be the cause. You can view replacement controllers in our Pump Controller category.

Step 7 – Test the Pump Directly

If hoses, filters and controller settings appear correct, test the pump directly. Disconnect it from the controller and connect it straight to a 12V battery. If the pump flows strongly, the issue lies in the wiring or controller. If it still produces little or no flow, the pump may be worn or the valves damaged.

When Replacement Is Necessary

Consider replacing components such as old hose, clogged filters, worn pumps or controllers that misread pressure. Regular inspections help prevent unexpected breakdowns and keep your system performing at its best.

Final Tips for Reliable Flow

Clean filters weekly, prevent debris from entering your tank, run the system regularly and store it in frost-free conditions. These simple steps eliminate most flow-related issues and keep your system running smoothly throughout the year.

Need Help Fixing Flow Problems?

Browse pumps, controllers and accessories at the Window Cleaning Stuff Shop. We stock thousands of products for fast UK delivery.

Related Products

Explore More Guides

Find more maintenance guides, fault-finding help and system advice on our Blog.

Shopping cart0
There are no products in the cart!
Continue shopping
0
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare